GET THE APP

RP-HPLC Method Development and Validation for Pioglitazone in Bulk and Marketed Formulation

Der Pharma Chemica
Journal for Medicinal Chemistry, Pharmaceutical Chemistry, Pharmaceutical Sciences and Computational Chemistry

ISSN: 0975-413X
All submissions of the EM system will be redirected to Online Manuscript Submission System. Authors are requested to submit articles directly to Online Manuscript Submission Systemof respective journal.

Research Article - Der Pharma Chemica ( 2021) Volume 13, Issue 6

RP-HPLC Method Development and Validation for Pioglitazone in Bulk and Marketed Formulation

Meenaxi M. Maste1*, Nikhil S. Gawas1, Utkarsh Shashtri2 and Poonam Shelar1
 
1Department of Pharmaceutical Chemistry, KLE College of Pharmacy Belagavi, KLE Academy of Higher Education and Research, Belagavi-560010, Karnataka, India
2Department of Pharmaceutics, KLE College of Pharmacy Belagavi, KLE Academy of Higher Education and Research, Belagavi-560010, Karnataka, India
 
*Corresponding Author:
Meenaxi M. Maste, Department of Pharmaceutical Chemistry, KLE College of Pharmacy Belagavi, KLE Academy of Higher Education and Research, Belagavi-560010, Karnataka, India, Email: menaimm@gmail.com

Received: 19-May-2021 Accepted Date: Jun 16, 2021 ; Published: 25-Jun-2021

Abstract

The work describes a precise, accurate and reproducible Reverse Phase High Performance Liquid Chromatographic (RP-HPLC) method for development and validation of Pioglitazone in tablet dosage form on Lachrome Liquid chromatographic system having PDA-20 A UV/VIS Detector using stationary phase C18 column (300 mm × 3.9 mm, 5 μm, particle size) and acetonitrile:phosphate buffer, (50:50 v/v) as mobile phase at flow rate of 1.00 ml/min and the detection wavelength was 267 nm. The retention time for Pioglitazone was found to be 8.08 min. The method was validated for precision, accuracy, linearity range, robustness, system stability, as per ICH guidelines Q2(R1).

Keywords

Pioglitazone, RP-HPLC, PDA detector, C18 column

Introduction

Pioglitazone an insulin sensitizer,S1] chemically a (RS)-5-(4-[2-(5-ethylpyridin-2-yl)ethoxy] benzyl)thiazolidine-2,4-dione an type 2 oral antdiabetic drug, sold under brand name Actoplus Met, Actos, Duetact, Glidipion, etc. Type 2 diabetes where the patients lack the capability of producing enough insuin in the body [1,2]. Pioglitazone activates a ligand-activated transcription factor PPAR-gamma, inducing cell differentiation and inhibiting cell growth and angiogenesis [3]. Pioglitazone inhibits macrophage and monocyte activation, adapts the transcription of insulin responsive genes, and stimulates adipocyte differentiation [4,5].

Pioglitazone enhances insulin sensitivity by making cells more responsive to it. In patients with type 2 diabetes, pioglitazone improves glycemic control mostly through enhancing peripheral insulin sensitivity, whereas metformin lowers hepatic glucose output. In hypoglycemic situations, pioglitazone masks symptoms such as increased heart rate, dizziness, and perspiration. It also has side effects such as edoema (when used with a sulfonylurea or insulin), heat failure, and respiratory infection. Due to the risk of urinary bladder cancer, pioglitazone was banned as an anti-diabetic medicine on July 18, 2013, however the prohibition was reversed on July 31, 2013 [6,7]. Literature survey reveals that, analytical and bio-analytical methods have been developed and validated for the estimation of Pioglitazone in bulk, pharmaceutical formulation and biofluids, which include techniques like HPLC, Spectrophotometry, and Polarography. [8-24] The current study has been undertaken to develop RP-HPLC method for the determination of Pioglitazone in bulk and pharmaceutical formulation.

Derpharma-chemica-Pioglitazone

Figure 1: Pioglitazone

Exprimental

Materials and Method

Pioglitazone was obtained as a gift sample from Dr. Reddy's Laboratories.Pioglitazone tablets were procured from the local market. HPLC grade Acetonitrile, AR grade Diammonium hydrogen orthophosphate, Potassium dihydrogen orthophosphate, orthophosphoric acid and triethylamine were used for the analysis, distilled water was utilized from Merkmilipore.

Instrument and Column

The Lachrom 2200 system equipped with auto sampler, and Lachrom elite control as the operating software. The chromatographic separation was carried out on C18 column, 300x3.9mm, 5μm (Bondapack column).

Preparation of Mobile Phase

Mixture of buffer (1.15 gm of diammonium hydrogen orthophosphate, 1.36 gm of potassium dihydrogen orthophosphate, 1ml triethylamine)and acetonitrile in the ratio of (50:50v/v)was filter, degased and used for analysis.

Preparation of Buffer

1.15gm of diammonium hydrogen orthophosphate, 1.36 gm of potassium dihydrogen orthophosphate and 1ml triethylamine was dissolved in 1000 ml water,pH was adjusted to 5.0 with orthophosphoric acid.

Preparation of Standard stock solution

30mg of Pioglitazone Hydrochloride was placed in 100ml volumetric flask and 10ml of dimethyl formamide was transferred to the volumetric flask and sonicated for 15 min. and the solution was made up to the mark using mobile phase. Then 2ml of the above solution was transferred to 25ml volumetric flask and the volume was made upto the mark using mobile phase.

Preparation of Sample Solution

Weighed and powder 20 tablets. Transferred equivalent weight 30mg of pioglitazone to a 100 ml volumetric flask. Add about 10 ml dimethyl formamide and sonicate for 5 min. Add 70 ml of mobile phase and sonicate for 10 min. Cool and dilute up to the mark with mobile phase . Filtered through whatman filter paper no.1. Transfer 2 ml of filtrate to 25 ml volumetric flask and dilute with mobile phase.

Chromatographic condition

The optimized chromatographic conditions and the optimized chromatogram for the newly developed method have been represented in Table 1 and Figure 2 respectively.

derpharma-chemica-Chromatogram

Figure 2:Optimized Chromatogram of Pioglitazone.

Table 1: Optimized Chromatographic Conditions.

Mobile Phase Filtered and degassed Buffer:Acetonitrile (50:50%v/v)
Stationary Phase Bondapack C18, 300×3.9 mm 5µm
Detection wavelength 267nm
Run Time 10 min
Flow rate 1.0 ml/min
Injection Volume 20 µL
Column Temperature 25° C
Retention Time 8.08 min

Method Validation

The method was validated as per ICH guidelines Q2(R1), in terms of System suitability, Linearity, Precision, Accuracy, and Robustness [25-30].

System Suitability Tests for Validation

System suitability tests is performed to ensure system performance before and duringthe analysis which demonstrates that the system is operating properly and ready todeliver results with acceptable accuracy and precision. Five replicate injections of a single standard solution were made on to a RP-HPLC system and the area of the pioglitazone peak was determined. USP Tailing for pioglitazone was recorded. The relative standard deviation of the peak area was calculated. The other parameters considered for system suitability were USP plate count for pioglitazone. The limit set and the values are reported given in Table 2.

Table 2: The limit set and the values obtained for system suitability.

Parameter Set limits Obtained Values
% RSD of peak area for five replicate injections for pioglitazone in 45 mg standard NMT 0.62%
2.00%
% RSD of retention time for five replicate injections for pioglitazone in 45 mg standard NMT 0.11%
1.00%
Theoretical Plate Count for Pioglitazone NLT 3886
2000

Linearity

The linearity of analytical procedure is its ability (within a given range) to obtain test results, which are directly proportional to the concentration of analyte in the sample [28]. 7 different solutions of pioglitazone ranging from 11.82 ppm to 35.46 ppm were prepared and analysed. Concentration was plotted on X-axis and area on Y-axis. Correlation coefficient and the equation of line were calculated. The data obtained and the graph of Linearity has been represented in Table 3 and Figure 3 respectively.

Table 3: The results of Linearity

Sr. no Volume taken (500 ppm) Total Volume (ml) Actual Conc (ppm) Peak Area Mean peak area
1 1 25 10 169275 170257
170691
170804
2 1.2 25 12 204612 205587
206184
205966
3 1.6 25 16 266659 266946
265541
268638
4 2 25 20 331110 333453
334424
334826
5 2.4 25 24 402532 401461
400117
401734
6 2.8 25 28 460898 460413
460217
460124
7 3 25 30 493432 495155
494924
497108
Slope 13644.42
Intercept 9678.82
Correlation coefficient (r2) 0.99987

Range

Five replicates of each linearity level, 50% level (lower level) and 150% (upperlevel) was injected and %RSD for retention time and area were determined. The data is summarized in Table 4.

Table 4: Values for Range`

Pioglitazone Level I Area Level VII RT Level I Area Level VII RT
  170643 7.99 500927 8
170110 7.99 506426 8.01
169748 8 501212 8
170814 7.99 503589 7.99
168114 7.99 506416 7.99
Mean 169886 7.99 503714 8
SD 1077.43 0.0045 2678.56 0.0084
%RSD 0.63 0.06 0.53 0.11

Precision

System Precision

Repeatability of pioglitazone standard in assay method.5 replicates of standard preparation were injected as per method parameters and the %RSD for the peak area and retention time was determined. The data has been summarized in Table 5.

Table 5: The data for System precision

Std weight. (mg) Area RT Tailing Theoretical Plates
30.5 326346 8 1.85 3829
324402 8 1.86 3862
323473 8 1.85 3832
320619 8 1.85 3874
324888 8 1.83 3866
Mean 323946 8 1.85 3853
SD 2130.02 0 - -
%RSD 0.66 0 - -

Method Precision

The assay percentage for each test preparation and the mean assay of six test preparation and %RSD for the same was calculated and the data is summarized in Table 6.

Table 6: The results of method precision.

Sample wt. (mg) Test Area % Assay
200.2 352251 99.9
202.9 360322 100.9
200.3 352105 99.8
200.6 350623 99.3
202.1 357253 100.4
202.9 360433 100.9
  Mean 100.2
SD 0.645
%RSD 0.64

Intermediate Precision

The intermediate precision was performed on different days, equipment and analyst. The data for interday precision has been given in Table 7, the data for intraday day has be en given in Tables 8 & 9 exhibits the results of one way ANOVA.

Table 7: The data for Interday Precision

Concentration (mg/ml) Area SD %RSD
10 Day 1 171275 715.5028535 0.416175536
Day 2 172691
Day 3 171804
20 Day 1 332110 852.5311334 0.256436332
Day 2 333424
Day 3 331826
30 Day 1 494432 876.669455 0.177061539
Day 2 494824
Day 3 496108

Table 8: The data for system suitability

Concentration (mg/ml) Area SD %RSD
10 1st Hour 169727 1677.66667 0.994010011
4th Hour 169691
8th Hour 166804
20 1st Hour 332100 2358.498675 0.710057526
4th Hour 334542
8th Hour 329826
30 1st Hour 482432 4271.592833 0.881599972
4th Hour 489442
8th Hour 481708

Table 9: Results for ANOVA test

Concentration (mg/ml) Area for interday Area for intraday
10 171275 169727
172691 169691
171804 166804
20 332110 332100
333424 334542
331826 329826
30 494432 482432
494824 489442
496108 481708
Results
F 0.005172
F crit 4.493998

Equipment used: HPLC

Make: Shimadzu

Model: Class VP

Column: C18, 300*3.9 mm, 5 μm (Bondapack is suitable)

Reproducibility

Blank preparation: Mobile phase is used as blank preparation.

Placebo preparation

170.4 mg of placebo is weighed and transferred to a 100 ml volumetric flask. 10 ml of dimethyl formamide was added and sonicated for about 5 minutes. 70ml of mobile phase was added and sonicated for 10 min. Cooled and diluted upto the mark with mobile phase followed by transfer of 2.0 ml of filtrate to a 25 ml volumetric flask, diluted to volume with mobile phase.

Sample preparation

202.5 mg of sample (equivalent to 30 mg of pioglitazone) is weighed and transferred to a 100 ml volumetric flask. 10 ml of dimethyl formamide was added and sonicated for about 5 minutes. 70ml of mobile phase was added and sonicated for 10 min. Cooled and diluted upto the mark with mobile phase followed by transfer of 2.0 ml of filtrate to a 25 ml volumetric flask, diluted to volume with mobile phase. In continuation with the above experiment prepare and analyze six different independent samples as per method. The assay percentage for each test preparation and The mean assay of six test preparation and %RSD for the same was calculated. The data obtained is summarized in Table 10.

Table 10: The data for system suitability

Std wt. (mg) Area RT Tailing Theoretical Plates
30.2 311532 7.793 1.84 4520
312515 7.72 1.88 4531
311729 7.773 1.85 4582
312154 7.729 1.83 4517
312273 7.739 1.84 4593
Mean 312041 7.743 1.85 4549
SD 402.3969 0.0288 - -
%RSD 0.13 0.37 - -

Accuracy

Known amount of the active ingredient at 3 levels each in triplicate, i.e. 3 x 80%, 3 x100% and 3 x 120% of the working concentration was spiked with placebo at 100 %level of 100 mg tablet samples were prepared in triplicate. Each sample was analyzedand calculated. The data for individual compound is summarized in Table 11.

Table 11: The results for accuracy

Level Wt. of Placebo (mg) Std wt. Level (mg) Area % Recovery Mean Recovery (%) SD %RSD
80% 171.2 26.6 285631 100.3 100.1 0.2 0.2
171.6 26.5 283474 99.9
171.5 26.4 283074 100.1
100% 171.1 33.2 353232 99.3 99.5 0.3215 0.32
171.8 33 352967 99.9
171.2 33.1 352258 99.4
120% 171 39.8 425230 99.8 99.9 0.0577 0.06
171.5 39.6 423806 99.9
171.1 39.9 426889 99.9

Robustness

To demonstrate the robustness of the test method checked the method suitability by injecting test solution into RP-HPLC with slight variations in method parameters[31]. Standard solution and test solution were prepared as per method of analysis. Once blank and five replicate of standard injection and sample solution in duplicate were injected. The mean % assay for sample solution with slight variation in method parameter was calculated. Changes in chromatographic conditions were as follows:

1. Change in flow ± 10%

2. Change in organic phase ± 10%

3. Change in pH ± 0.2

The values for Robustness has been represented in Tables 12-17, and the chromatogram of blank solution has been represented in Figure 3.

Results and Discussions

To develop RP-HPLC method, several mobile phase and mobile phase compositions were tried. A satisfactorily separate and good peak symmetry was obtained with Bondapack 300*3.9mm 5μm C18 column using mobile phase Acetonitrile:Buffer (50:50%v/v) and flow rate 1.0 ml per min. The detection was carried out 267 nm and the retention time was found to be 8.08 min.

System Suitability for validation

Five replicate injections of a single standard solution were made on to a RP-HPLC system and the area of the pioglitazone peak was determined. USP Tailing for pioglitazone was recorded. The relative standard deviation of the peak area was calculated. The other parameters considered for system suitability were USP plate count for pioglitazone. The limit set and the values obtained are in below in Table 2.

Linearity and Range

Under optimised condition the different concentration vs area was plotted in the range from 11.82 ppm to 35.46 ppm. The graph was found to be linear for concentration range and has been given in Figure 3. The data has been given in Tables 3 and 4.

Derpharma-chemica-calibration

Figure 3: Calibration Curve (linearity of PiolitazoneHCl at 267nm)

For precision studies; system precision as one of the parameter the sample was injected in 5 replicates and area, standard deviation and % RSD was calculated, it was expected and found to be less than 2% [32]. The data for system precision has been summarized in Table5, method precision in Table 6, interday and intra day precision in Table 7 and 8, and reproducibility in Table 10.

Accuracy: For accuracy of the method, pioglitazone HCl was analyzed at three different levels in triplicates and the %RSD was calculated. The %RSD was found to be less than 2%.

Robustness

Under the selected experimental conditions, the standard and sample preparation run was carried out and % assay values were calculated. The data obtained for change in flow rate by +10% and -10% was summarised in Table 12 and Table 13 respectively. The data obtained for change organic phase by +10% and -10% has been summarised in table 14 and 15 respectively. And the data for change in pH +0.2 and -0.2 is summarized Table 16 and Table 17 respectively.

Table 12: The results obtained for +10% flow rate in Robustness.

Sample weight in( mg) Area %Assay
200.2 314093 100.1
202.9 32004 100.7
200.3 313188 99.88
  Mean 100.2
SD 0.4583
%RSD 0.46

Table 13: The results obtained for -10% flow rate in Robustness.

Sample weight in( mg) Area %Assay
200.2 385904 100.4
202.9 390512 100.2
200.3 386249 100.4
  Mean 100.3
SD 0.1155
%RSD 0.12

Table 14: Results for %RSD for robustness (+10% organic phase)

Sample weight in( mg) Area %Assay
200.6 303435 100.6
202.7 302839 100.4
202.9 301986 100
  Mean 100.3
SD 0.3055
%RSD 0.3

Table 15: Results for % RSD for robustness (-10% organic phase)

Sample weight in( mg) Area %Assay
200.6 448627 99.2
201.4 452667 99.7
201.1 452914 99.9
  Mean 99.6
SD 0.3606
%RSD 0.36

Table 16: Results for RSD for robustness (pH+0.2 i.e. pH of buffer 5.2)

Sample weight in( mg) Area %Assay
202 355868 99.3
201.3 354766 99.3
202.9 359857 100
  Mean 99.5
SD 0.4041
%RSD 0.41

Table 17: Results for RSD for robustness (pH-0.2 i.e. pH of buffer 4.8)

Sample weight in( mg) Area %Assay
202.5 366165 100.3
202.1 362891 99.6
202.1 364282 100
  Mean 100
SD 0.3512
%RSD 0.35

Conclusion

The validated RP-HPLC assay method for pioglitazone can be used for determination of its purity.The method has been shown to be specific, linear, precise and accurate across a suitable analytical range for pioglatazone. Solutions have been shown to be stable for at least 24 hours on ambient storagecondition.This method was found to be better in consideration of other reported methods for individual drugs, because of economical readily available mobile phase, UV detection and better resolution of peak.This method will be advantageous for rapid quantification of sample in routine and quality control analysis for bulk and pharmaceutical dosage form containing pioglitazone.

References

Select your language of interest to view the total content in your interested language

30+ Million Readerbase
SCImago Journal & Country Rank
Google Scholar citation report
Citations : 15261

Der Pharma Chemica received 15261 citations as per Google Scholar report

Der Pharma Chemica peer review process verified at publons
Der Pharma Chemica- Journals on pharmaceutical chemistry