UV-VIS absorbance measurement is a widely used and well established monitoring method for the kinetic study of various chemical reactions. The present study is carried out to evaluate applicability of pH measurement method, specially, for monitoring non-aqueous mediated chemical reactions along with UV-VIS absorbance measurement method. The rate constant values obtained by pH measurement were moderately in agreement with that by absorbance measurement method, which suggests that pH measurement could be used to monitor the reactions to get preliminary information about the kinetic aspect of the reactions.